Utiliguard Models

We offer six Utiliguard models.
Details and more information on all the models are available below or CLICK HERE for a sheet comparing the capabilities and specifications.


Model- ECP - Efficiency Control Processor
The ECP unit fine-tunes the electrical system in your home or facility. This fine tuning reduces heat generation, reduces amperage and results in reduced consumption of electricity. It causes less waste of electrical energy while increasing the life of the inductive equipment in your home or office. It protects
against power surges and increases the capacity to the electrical panel by making it run cooler.

Download File


Model 240 DELTA - 120/240 DELTA
♦ Wiring - 4 wire plus ground
♦ Maximum Surge Current (Peak Current) - 100kA per phase (100,000 amps)
♦ Response Time < 85 picoseconds
♦ Clamp Voltage (Vpeak) - Cat. C1/B3 ANSI/EEEE - C62.41-1991-(6kV-1.2/5.0 us,3kA-8/20 us)
♦ Total Capacitance (F:1Mhz) - 19,000 per leg, 57,000 total
♦ Relative Humidity Range - 100%
♦ Operating Frequency - 50-60 Hrtz
♦ Operating Temp. Range (Celsius) - -55 to +85
♦ Joules Rating - 1000 per leg, 1600 hi-leg, 3600 total

Download File


Model 208 WYE - 120/208 WYE Type 1
♦ Wiring - 4 wire plus ground
♦ Maximum Surge Current (Peak Current) - 100kA per phase (100,000 amps)
♦ Response Time < 85 picoseconds
♦ Clamp Voltage (Vpeak) - Cat. C1/B3 ANSI/EEEE - C62.41-1991-(6kV-1.2/5.0 us,3kA-8/20 us)
♦ Total Capacitance (F:1Mhz) - 19,000 per leg, 11,000 hi-leg, 49,000 total
♦ Relative Humidity Range - 100%
♦ Operating Frequency - 50-60 Hrtz
♦ Operating Temp. Range (Celsius) - -55 to +85
♦ Joules Rating - 1000 per leg, 1600 hi-leg, 3600 total

Download File


Model 480 WYE - 277/480 WYE
♦ Wiring - 4 wire plus ground
♦ Maximum Surge Current (Peak Current) - 100kA per phase (100,000 amps)
♦ Response Time < 85 picoseconds
♦ Clamp Voltage (Vpeak) - Cat. C1/B3 ANSI/EEEE - C62.41-1991-(6kV-1.2/5.0 us,3kA-8/20 us)
♦ Total Capacitance (F:1Mhz) - 7,500 per leg, 22,500 total
♦ Relative Humidity Range - 100%
♦ Operating Frequency - 50-60 Hrtz
♦ Operating Temp. Range (Celsius) - -55 to +85
♦ Joules Rating - 2,730 per leg, 8,190 total

Download File


Model SP240 - 120/240 Single Phase
♦ Wiring - 3 wire plus ground
♦ Maximum Surge Current (Peak Current) - 100kA per phase (100,000 amps)
♦ Response Time < 85 picoseconds
♦ Clamp Voltage (Vpeak) - Cat. C1/B3 ANSI/EEEE - C62.41-1991-(6kV-1.2/5.0 us,3kA-8/20 us)
♦ Total Capacitance (F:1Mhz) - 19,000 per leg, 38,000 total
♦ Relative Humidity Range - 100%
♦ Operating Frequency - 50-60 Hrtz
♦ Operating Temp. Range (Celsius) - -55 to +85
♦ Joules Rating - 1000 per leg, 2000 total

Download File


Model RUTL - 120/240 Single Phase
♦ Wiring - 3 wire plus ground
♦ Maximum Surge Current (Peak Current) - 70kA per phase (70,000 amps)
♦ Response Time < 85 picoseconds
♦ Clamp Voltage (Vpeak) - Cat. C1/B3 ANSI/EEEE - C62.41-1991-(6kV-1.2/5.0 us,3kA-8/20 us)
♦ Total Capacitance (F:1Mhz) - 13,300 per leg, 26,600 total
♦ Relative Humidity Range - 100%
♦ Operating Frequency - 50-60 Hrtz
♦ Operating Temp. Range (Celsius) - -55 to +85

Download File